SPIDRlive™ - Streaming Live Well Test Data

SPIDRlive

SPIDRlive is the result of an evolution of the SPIDR technology. SPIDRlive features all the same quartz performance specifications of the classic SPIDR and now enhanced with the ability to stream the data through the cloud to a secure web-based dashboard for remote visualization on your mobile device for realization of what’s happening at your wellsite as it’s happening! SPIDRlive is ideally suited for frac interaction monitoring applications.

Benefits

  • Monitor in real-time from remote locations for unconventional reservoir performance monitoring of DFIT, frac interactions of offset wells or CALIBR™ engineered post-frac flowback
SPIDR Web
Streaming “live” well test data for frac interaction monitoring
  • Capture high resolution and high-frequency data necessary to perform pressure transient analysis from the wellhead
  • Accurately calculate bottomhole pressure from wellhead measurements
  • Determine skin, permeability and reservoir pressure without running any equipment downhole
  • View and download data in real-time with no data interruption
  • Memory and battery life enable data recording for up to 2 years, depending on sample frequency
  • Powered by alkaline batteries with no hazardous materials limitations

Features

  • Dual-quartz pressure transducer 0.01 psi resolution
  • Up to 1-second sample frequency
  • Pressure data compensated for ambient temperature change
  • Powered by alkaline batteries
  • 10,000 or 15,000 psi
  • Capable of storing over 16 million samples
  • Intelligent sampling to condense file size
  • Capillary tube connection to isolate the SPIDR from wellhead temperature effects
  • 1/2-inch NPT or 9/16-inch autoclave connection
  • Wireless communication to a field Edge device
  • Streaming well data through the cloud to your designated mobile device
SPIDRlive Specifications
Full-Scale Pressure 10,000 or 15,000 psia
Resolution 0.01-psi
Accuracy 0.025% of Full Scale
Transducer Quartz
Memory Capacity 16,000,000 data sets (in single mode)
Nominal Sampling 1-sample per second
Power 8 x Alkaline D-Cell Batteries
Thermal Compensation Indicated pressures unaffected by ambient temperature changes within the operating ambient temperature range
Operating Temperature Range -20F to 130F
Connections ½” NPT Connection for 10,000-psi
9/16” Autoclave for 15,000-psi
Communication Wireless to the Edge; cellular from Edge to the Cloud